Trash & linen chutes
Gravity Chutes & Intakes
We build our chutes in our own shop to NFPA 82 and current building code. 24" diameter is standard, with UL-labeled intake doors, discharge outlets and roof vents. Every door is made to whatever size your building needs.
General arrangement
24"Standard diameter
1½hrUL Label "B" doors
NFPA82Design basis
CustomDoor sizes
| Chute CL to finished wall | 20 1/2" |
|---|---|
| Intake face from chute | 8 1/2" |
| Intake section height | 47 1/2" |
| Intake doors | Bottom- or side-hinged, custom-sized to each building |
| Roof termination | 48" min. with explosion cap, or 96" min. with side louver |
- 18/16 ga aluminized steel or type 304 stainless
- Vertical seams lapped and welded; slip joint every floor
- 2" x 2" x 1/8" steel angle floor frames
- Flush head and sprinklers at the top intake floor
- Outlets: O, R, RB, THT, THL
- Explosion cap or 24" x 24" side louver at the roof
- Washdown / sanitizing unit (ADSU)
- Intake door interlocks
- Rubber baffles
- Sound-dampening coating

Got a building coming up?
Send us the plans.
We'll take it from there.
We'll take it from there.